PRODUCTS

Seantec provides a wide variety of high-performance thermal and EMI materials,to meet the divers needs and innovation requirements of customer in various industries.

Thermal pads
Tflex™ 600 Series Thermal Gap Filler
Tflex™ 600 is an exceptionally soft, highly compliant gap filling interface pad with a thermal conductivity of 3 W/mK. These outstanding properties are the result of a proprietary boron nitride filler in the composition.
DOWNLOAD
PRODUCT DESCRIPTION
TYPICAL PROPERTY DATA
SPECIFICATIONS

EXCEPTIONALLY SOFT, HIGHLY COMPLIANT GAP FILLER


Tflex™ 600 is an exceptionally soft, highly compliant gap filling interface pad with a thermal conductivity of 3 W/mK. These outstanding properties are the result of a proprietary boron nitride filler in the composition. 


The high conductivity, in combination with extreme softness produces incredibly low thermal resistances.


Tflex™ 600 is naturally tacky and requires no additional adhesive coating that can inhibit thermal performance. Tflex™ 600 is electrically insulating, stable from –45°C to 200°C and meets UL 94 V0 rating.


FEATURES AND BENEFITS


  • Very high compliancy for low stress applications

  • 3 W/mK thermal conductivity

  • Available in thicknesses from 0.020” - 0.200” (0.5mm - 5.0mm)

  • Naturally tacky, needs no further adhesive coating


APPLICATIONS


  • Cooling components to the chassis or frame

  • High speed mass storage drives

  • RDRAM memory modules

  • Heat pipe thermal solutions

  • Automotive engine control units

  • Telecommunications hardware


STANDARD THICKNESSES


0.020 to 0.200-inch (0.5 to 5.0mm)

0.020 to 0.200-inch thick material available in 0.010-inch (0.25mm) increments

Inquire about availability of material and options above 0.200-inches


STANDARD SHEET SIZES


9 x 9” (229 x 229mm). 18 x 18” (457 x 457mm). 9 x 9” only over 0.100” thickness. TflexTM 600 

can be die cut to individual shapes. Pressure sensitive adhesive is not applicable for TflexTM 600 products.


TACKY ONE SIDE ONLY


Tflex™ 600 is naturally tacky on both sides. Tflex™ 600 can be provided tacky on one side only. 

This is indicated by the suffix “DC1”. This option offers good separation properties allowing the 

tacky side to stick to the heatsink/chasis/cold plate/etc. and the other “dry” side to release easily 

from the component(s).


REINFORCEMENT


Fiberglass is required in 0.020” (0.51mm) and 0.030” (0.76mm). Thicknesses of 0.040” (1.02mm) 

and above do not require reinforcement. Data for design engineer guidance only. Observed 

performance varies in application. Engineers are reminded to test the material in application.


SPECIFICATIONS


微信截图_20221031085323.png


PRE:THE LAST ONE
NEXT:THE LAST ONE

MESSAGE

Please leave your message to get the Datasheet,For more information we will contact you by email.Thanks!

DOWNLOAD DATASHEET